Power Quality Management Software

GeoEner PQM

Continuously monitors voltage sags, harmonics, flicker and unbalance; automatically audits against EN 50160 and regulatory power quality criteria, and produces audit-ready reports.

10 yıl
Measurement archive with a compression policy
1 / 10 dk
Synchronized measurement windows, IEC 61000-4-30
ms
Early-warning resolution for voltage sags and swells
Marka-bağımsız
One roof via Modbus, OPC UA and REST

About the Product

GeoEner PQM is power quality management software that measures, monitors and proves the technical quality of the electricity grid. It collects vendor-independent data from field power quality analyzers via Modbus, OPC UA and REST, and standardizes all measurements in a single time-series archive with 10-year retention. It captures voltage sags, swells, interruptions and transients at millisecond resolution with instant alarms, and automatically audits voltage magnitude, unbalance, harmonics and flicker using EN 50160 and IEC 61000-4-30 methodology. Regulatory power quality reports (standard tables, weekly voltage sag table, raw data export) are produced in one click; measurement points are scored against regulatory limits, pinpointing weak spots per feeder and transformer. Root cause analysis helps distinguish whether a disturbance originates upstream (grid) or downstream (consumer). Reports are available as PDF, Excel, CSV and HTML, can be pushed to SAP-side services via EDVARS integration, and delivered by scheduled e-mail. Built for distribution companies, industrial facilities, organized industrial zones and large consumers; supports LDAP/SSO and role-based authorization.

Key Features

Real-time monitoring

Captures voltage sags, swells, interruptions and transients at millisecond level and raises instant alarms.

sag · swell · interruption · transient
EN 50160 compliance

Automatically audits voltage magnitude, unbalance, harmonics and flicker using the standard measurement window.

IEC 61000-4-30 methodology
Regulatory technical quality reports

Standard tables 1/2/3/5, the weekly voltage sag table and raw data exports — produced audit-ready.

Tables 1 · 2 · 3 · 5
Automatic performance scoring

Scores measurement points against regulatory limits and pinpoints weak spots per feeder and transformer.

Per feeder and transformer
Root cause analysis

Helps determine whether a disturbance originates on the grid side or the consumer side.

upstream / downstream
Device-independent architecture

Standardizes power quality recorders of any brand and model in a single database.

Modbus · OPC UA · REST
Harmonics, flicker, unbalance

Tracks individual harmonics, total distortion and negative sequence, with optional IEEE 519 voltage/current auditing.

THD · Pst/Plt · u₂ · TDD
Dynamic dashboard and map

KPIs, event trends, the weak-spot list and a live map bring the state of the grid onto a single screen.

widget · trend · live map
Reporting and integration

Ready-made regulatory templates stay audit-ready at all times, with automatic performance scoring charted over weekly and monthly windows. Prepared reports are pushed to SAP-side services through EDVARS integration and delivered straight to stakeholders by scheduled e-mail.

PDF · Excel · CSV · EDVARS

Additional Modules

Real-Time MonitoringCompliance EngineRegulatory ReportingPerformance ScoringRoot Cause AnalysisDashboard & Live MapIntegration (EDVARS/SAP)Time-Series Archive

How It Works

  1. 01
    Collect — field devices

    Measurements are taken from power quality analyzers over Modbus, OPC UA and REST, independent of brand and model.

  2. 02
    Store — time-series archive

    All measurements are standardized in a single database and archived for 10 years with compression and retention policies.

  3. 03
    Analyze — compliance engine

    EN 50160, regulatory and IEEE 519 criteria are audited, and a performance score is computed for each measurement point.

  4. 04
    Deliver — reports and dashboards

    Output is produced through dashboards, regulatory reports and EDVARS export; reports reach stakeholders by scheduled e-mail.

Who It's For

Distribution companies

Audit technical quality obligations automatically, produce regulatory reports in one click and target weak feeders precisely.

Industrial facilities

Spot sags and harmonics affecting the production line early, identify their source and reduce losses.

Industrial zones and large consumers

Monitor quality issues on the shared grid and clarify liability boundaries with data.

Technical Summary

Standards
EN 50160 (voltage characteristics), IEC 61000-4-30 (Class A/S measurement), IEEE 519 (harmonic limits), national technical quality regulations and service quality directives
Data acquisition
Modbus, OPC UA, REST — device-independent adapter architecture
Archive
Time-series archive with a compression policy and 10-year retention
Report formats
PDF, Excel (.xlsx), CSV, HTML, e-mail
Regulatory reports
Standard tables 1/2/3/5, weekly voltage sag table, raw data export
Integration
Export to SAP services via EDVARS; scheduled e-mail delivery
Analysis scope
THD, individual harmonics, Pst/Plt flicker, negative sequence (u₂), TDD
Security and access
LDAP / SSO, role-based authorization

Frequently Asked Questions

Which standards does GeoEner PQM audit against?

GeoEner PQM automatically audits voltage magnitude, unbalance, harmonics and flicker using EN 50160 and IEC 61000-4-30 methodology, with optional IEEE 519 auditing. It produces regulatory power quality reports (standard tables, the weekly voltage sag table and raw data exports) in one click, and collects vendor-independent data from analyzers via Modbus, OPC UA and REST.

What is GeoEner PQM?

Continuously monitors voltage sags, harmonics, flicker and unbalance; automatically audits against EN 50160 and regulatory power quality criteria, and produces audit-ready reports.

Who is GeoEner PQM for?

Distribution companies: Audit technical quality obligations automatically, produce regulatory reports in one click and target weak feeders precisely. Industrial facilities: Spot sags and harmonics affecting the production line early, identify their source and reduce losses. Industrial zones and large consumers: Monitor quality issues on the shared grid and clarify liability boundaries with data.

How does GeoEner PQM work?

1. Collect — field devices — Measurements are taken from power quality analyzers over Modbus, OPC UA and REST, independent of brand and model. 2. Store — time-series archive — All measurements are standardized in a single database and archived for 10 years with compression and retention policies. 3. Analyze — compliance engine — EN 50160, regulatory and IEEE 519 criteria are audited, and a performance score is computed for each measurement point. 4. Deliver — reports and dashboards — Output is produced through dashboards, regulatory reports and EDVARS export; reports reach stakeholders by scheduled e-mail.

Which systems and standards does GeoEner PQM work with?

Standards: EN 50160 (voltage characteristics), IEC 61000-4-30 (Class A/S measurement), IEEE 519 (harmonic limits), national technical quality regulations and service quality directives. Report formats: PDF, Excel (.xlsx), CSV, HTML, e-mail. Integration: Export to SAP services via EDVARS; scheduled e-mail delivery.

Benefits

  • Audit-ready regulatory reports in one click
  • Vendor-independent: all analyzers on one platform
  • 10-year measurement archive
  • Liability boundaries clarified with data

Request a demo

Get in touch to see the product in action.

Contact Us
Better together
GeoEner PQM + GeoEner

A platform that digitalizes asset, investment and maintenance management end-to-end for electricity distribution and energy companies, with geographic information system (GIS) support.

GeoEner — explore
Better together
GeoEner PQM + GEONIVA

Generates drone missions from work orders, scans drone and field photos with AI, links each finding to the right grid equipment and writes approved findings into the maintenance form. Known in GeoEner as Inspection Management, it is the inspection module of the GEOENER family.

GEONIVA — explore
Better together
GeoEner PQM + GeoEner Tedarik Sürekliliği

Supply continuity management for electricity distribution companies, from outage record to EPDK report and compensation: staged outage records, affected installations calculated from the network topology, EPDK tables and the Customer Interruption Record, compensation, quality control and an outage map in one application.

GeoEner Tedarik Sürekliliği — explore

Let's start your digital transformation together